Model | ||||||||||
Input Side | ||||||||||
Max Power (kW) | 39 | 42.9 | 45.5 | 46.8 | ||||||
Max Voltage (V) | 1000 | |||||||||
Start-up DC Input Voltage (V) 250 | ||||||||||
MPPT Operating Range (V) | 200-850 | |||||||||
Max. DC Input Current (A) | 40+40 | |||||||||
Max. Short Circuit Current (A) | 60+60 | |||||||||
No.of MPP Trackers | 2 | |||||||||
No.of Strings per MPP Tracker | 3+3 | |||||||||
Output Side | ||||||||||
Rated Output Power (kW) | 30 | 33 | 35 | 36 | ||||||
Max. Active Power (kW) | 33 | 36.3 | 38.5 | 39.6 | ||||||
Nominal Output Voltage / Range (V) 3L/N/PE 220/380V, 230/400V | ||||||||||
Rated Grid Frequency (Hz) | 50 / 60 (Optional) | |||||||||
Operating Phase | Three Phase | |||||||||
Rated AC Grid Output Current (A) | 45.5/43.5 | 50/47.8 | 53/50.7 | 54.5/52.2 | ||||||
Max. AC Output Current (A) | 50/47.9 | 55/52.6 | 58.3/55.8 | 60/57.4 | ||||||
Output Power Factor | 0.8 leading to 0.8 lagging | |||||||||
Grid Current THD | <3% | |||||||||
DC Injection Current (mA) | <0.5% | |||||||||
Grid Frequency Range | 45~55 or 55~65 (Optional) | |||||||||
size and design | ||||||||||
Max. Efficiency | 98.6% | |||||||||
Euro Efficiency | 97.8% | |||||||||
MPPT Efficiency | >99%Yes | |||||||||
Protection | ||||||||||
DC Reverse-Polarity Protection | ||||||||||
AC Short Circuit Protection | Yes | |||||||||
AC Output Overcurrent Protection | Yes | |||||||||
Output Overvoltage Protection | Yes | |||||||||
Insulation Resistance Protection | Yes | |||||||||
Ground Fault Monitoring | Yes | |||||||||
Anti-islanding Protection | Yes | |||||||||
Temperature Protection | Yes | |||||||||
Integrated DC Switch | Yes | |||||||||
Remote Software Upload | Yes | |||||||||
Remote Change of Operating Parameters | Yes | |||||||||
Protect | DC Type II / AC Type II | |||||||||
General Data | ||||||||||
Cabinet Size (WxHxD mm) | 362×577×215 (Excluding Connectors and Brackets) | |||||||||
Weight (kg) | 23 | |||||||||
Topology | Transformerless | |||||||||
Internal Consumption | <1W (Night) | |||||||||
Running Temperature | -25-65℃, >45℃ Derating | |||||||||
Ingress Protection | IP65 | |||||||||
Noise Emission (Typical) | ≤50 dB | |||||||||
Cooling Concept | Smart Cooling | |||||||||
Permissible Altitude (m) | 2000 | |||||||||
Warranty | 5 Years | |||||||||
Grid Connection Standard | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1, G98, G99, C10- 11, UNE217002, NBR16149/NBR16150 | |||||||||
Operating Surroundings Humidity | 0- 100% | |||||||||
Safety EMC / Standard IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2 | ||||||||||
Features | ||||||||||
DC Connection | MC-4 Mateable | |||||||||
AC Connection | IP65 Rated Plug | |||||||||
Display | LCD1602 | |||||||||
Interface | RS485/RS232/Wifi/LAN |