| SUN-1K-G04 P1-EU-AM1 | ||||||||||||
| Input Side | ||||||||||||
| Max. DC Input Power (kW) 1.3 2 2.6 2.9 3.3 3.5 3.9 4.3 4.7 5.2 | ||||||||||||
| Max. DC Input Voltage (V) 550 | ||||||||||||
| Start-up DC Input Voltage (V) | 80 | |||||||||||
| MPPT Operating Range (V) | 70~500 | |||||||||||
| Max. DC Input Current (A) | 13 | |||||||||||
| Max. Short Circuit Current (A) | 19.5 | |||||||||||
| No.of MPP Trackers | 1 | |||||||||||
| No.of Strings per MPP Tracker | 1 | |||||||||||
| Output Side | 3 | |||||||||||
| Rated Output Power (kW) | 1 | 1.5 | 2 | 2.2 | 2.5 | 2.7 | 3 | 3.3 | 3.6 | 4 | ||
| Max. Active Power (kW) | 1.1 | 1.65 | 2.2 | 2.42 | 2.75 | 2.97 | 3.3 | 3.63 | 3.96 | 4.4 | ||
| Nominal Output Voltage / Range (V) | L/N/PE 220/230V (Optional) | |||||||||||
| Rated Grid Frequency (Hz) | 50 / 60 (Optional) | |||||||||||
| Operating Phase | Single Phase | |||||||||||
| Rated AC Grid Output Current (A) | 4.6/4.4 | 6.8/6.5 | 9. 1/8.7 | 10/9.6 | 11.4/10.9 | 12.3/11.8 | 13.7/13. 1 | 15/14.4 | 16.4/15.7 | 18.2/17.4 | ||
| Max. AC Output Current (A) | 5/4.8 | 7.5/7.2 | 10/9.6 | 11/10.6 | 12.5/12 | 13.5/13 | 15/14.4 | 16.5/15.8 | 18/17.3 | 20/19.2 | ||
| Output Power Factor | 0.8 leading to 0.8 lagging | |||||||||||
| Grid Current THD | <3% | |||||||||||
| DC Injection Current (mA) | <0.5% | |||||||||||
| Grid Frequency Range | 45~55 or 55~65 (Optional) | |||||||||||
| Efficiency | 97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.5% | 97.5% | 97.5% | 97.5% | ||
| Max. Efficiency | ||||||||||||
| Euro Efficiency | 97. 1% | 97. 1% | 97. 1% | 97. 1% | 97. 1% | 97. 1% | 97.3% | 97.3% | 97.3% | 97.3% | ||
| MPPT Efficiency | >99% | |||||||||||
| Protection | ||||||||||||
| DC Reverse-Polarity Protection | Yes | |||||||||||
| AC Short Circuit Protection | Yes | |||||||||||
| AC Output Overcurrent Protection | Yes | |||||||||||
| Output Overvoltage Protection | Yes | |||||||||||
| Insulation Resistance Protection | Yes | |||||||||||
| Ground Fault Monitoring | Yes | |||||||||||
| Anti-islanding Protection | Yes | |||||||||||
| Temperature Protection | Yes | |||||||||||
| Integrated DC Switch | Yes | |||||||||||
| Remote Software Upload | Yes | |||||||||||
| Remote Change of Operating Parameters | Yes | |||||||||||
| Surge Protection | DC Type II / AC Type II | |||||||||||
| General Data | ||||||||||||
| Cabinet Size (WxHxD mm) | 280×310×184 (Excluding Connectors and Brackets) | |||||||||||
| Weight (kg) | 4.8 | |||||||||||
| Topology | Transformerless | |||||||||||
| Internal Consumption | <1W (Night) | |||||||||||
| Running Temperature | -25~65℃, >45℃ Derating | |||||||||||
| Ingress Protection | IP65 | |||||||||||
| Noise Emission (Typical) | ≤35 dB | |||||||||||
| Cooling Concept | Free Cooling | |||||||||||
| Permissible Altitude (m) | 2000 | |||||||||||
| Warranty | 5 Years | |||||||||||
| Grid Connection Standard | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1, G98, G99, C10- 11, UNE217002, NBR16149/NBR16150 | |||||||||||
| Operating Surroundings Humidity | 0- 100% | |||||||||||
| Safety EMC / Standard IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2 | ||||||||||||
| Features | ||||||||||||
| DC Connection | MC-4 Mateable | |||||||||||
| AC Connection | IP65 Rated Plug | |||||||||||
| Display | LCD1602 | |||||||||||
| Interface | RS485/RS232/Wifi/LAN | |||||||||||