The intelligent monitoring platform also supports firmware update function. With the continuous advancement of technology and changes in market demand, photovoltaic power stations need to continuously upgrade equipment to remain competitive. Through the firmware update function of the intelligent monitoring platform, operation and maintenance personnel can obtain the latest software version at any time and remotely push the update program to the inverter product for installation. In this way, the equipment of the photovoltaic power station is always in optimal condition, improving power generation efficiency and stability.
● 100% unbalanced output, each phase
● AC couple to retrofifit existing solar system
● *Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
● Max. charging/discharging current of 50A
● High voltage battery, higher effificiency
● The most suitable charging process for lithium-ion batteries is to first precharge (restorative charge) the fully discharged battery cells, then perform constant current charging in a constant current mode, and finally perform constant voltage charging in a constant voltage mode.
● A diesel generator is a common backup power device that converts fuel, such as diesel, into electricity. This conversion process involves a combustion process in which fuel reacts with oxygen to produce heat and gases that move a piston, which in turn spins a crankshaft, and is ultimately converted into electricity by a generator.
SUN-5K-SG01 | SUN-6K-SG01 | SUN-8K-SG01 | SUN-10K-SG01 | SUN-12K-SG01 | SUN-15K-SG01 | SUN-20K-SG01 | SUN-25K-SG01 | |||||||||
Model | HP3-EU-AM2 | HP3-EU-AM2 | HP3-EU-AM2 | HP3-EU-AM2 | HP3-EU-AM2 | HP3-EU-AM2 | HP3-EU-AM2 | HP3-EU-AM2 | ||||||||
Battery Input Data | ||||||||||||||||
Battery Type | Lithium-ion | |||||||||||||||
Battery Voltage Range (V) | 160~700 | |||||||||||||||
Max. Charging Current (A) | 37 | 50 | ||||||||||||||
Max. Discharging Current (A) | 37 | 50 | ||||||||||||||
Number of Battery Input 1 | ||||||||||||||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||||||||||||||
PV String Input Data | ||||||||||||||||
Max. DC Input Power (W) | 6500 | 7800 | 10400 | 13000 | 15600 | 19500 | 26000 | 32500 | ||||||||
Max. DC Input Voltage (V) | 1000 | |||||||||||||||
Start-up Voltage (V) 180 | ||||||||||||||||
MPPT Range (V) | 150-850 | |||||||||||||||
195-850 | 195-850 | 260-850 | 325-850 | 340-850 | 420-850 | 500-850 | 625-850 | |||||||||
600 | ||||||||||||||||
20+20 | 26+26 | |||||||||||||||
30+30 | 39+39 | |||||||||||||||
No.of MPP Trackers 2 | ||||||||||||||||
No.of Strings per MPP Tracker | 1+1 | 2+1 | 2+2 | |||||||||||||
AC Output Data | ||||||||||||||||
Rated AC Output and UPS Power (W) | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 | ||||||||
Max. AC Output Power (W) | 5500 | 6600 | 8800 | 11000 | 13200 | 16500 | 22000 | 26000 | ||||||||
AC Output Rated Current (A) | 7.6/7.3 | 9. 1/8.7 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 | 22.8/21.8 | 30.4/29 | 37.9/36.3 | ||||||||
Max. AC Output Rated Current (A) | 8.4/8 | 10/9.6 | 13.4/12.8 | 16.7/16 | 20/19.2 | 25/24 | 33.4/31.9 | 39.4/37.7 | ||||||||
Max. Three-phase Unbalanced Output Current(A) | 13 | 13 | 18 | 22 | 25 | 30 | 35 | 40 | ||||||||
Max. Continuous AC Passthrough (A) | 40 | 80 | ||||||||||||||
Peak Power (off grid) | 1.5 time of rated power, 10 S | |||||||||||||||
Generator Input/Smart Load /AC Couple Current (A) | 7.6/40/7.6 | 9. 1/40/9. 1 | 12.2/40/12.2 | 15.2/40/15.2 | 18.2/80/18.2 | 22.8/80/22.8 | 30.4/80/30.4 | 37.9/80/37.9 | ||||||||
Power Factor | 0.8 leading to 0.8 lagging | |||||||||||||||
Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | |||||||||||||||
Grid Type | Three Phase | |||||||||||||||
Total Harmonic Distortion (THD) | <3% (of nominal power) | |||||||||||||||
DC Current Injection | <0.5% In | |||||||||||||||
Efficiency | ||||||||||||||||
Max. Efficiency | 97.60% | |||||||||||||||
Euro Efficiency | 97.00% | |||||||||||||||
MPPT Efficiency | 99.90% | |||||||||||||||
Protection | ||||||||||||||||
Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, | |||||||||||||||
Output Shorted Protection, Surge Protection | ||||||||||||||||
Over Voltage Category | DC Type II/AC Type III | |||||||||||||||
Certifications and Standards | ||||||||||||||||
Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1, G98, G99, C10- 11, UNE217002, NBR16149/NBR16150 | |||||||||||||||
Safety EMC / Standard | IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2 | |||||||||||||||
General Data | ||||||||||||||||
Operating Temperature Range (C) | -40-60℃, >45℃ Derating | |||||||||||||||
Cooling | Smart Cooling | |||||||||||||||
Noise (dB) | ≤55 dB | |||||||||||||||
Communication with BMS | RS485; CAN | |||||||||||||||
Weight (kg) | 30.5 | |||||||||||||||
Cabinet Size (WxHxD mm) | 408×638×237 (Excluding Connectors and Brackets) | |||||||||||||||
Protection Degree | IP65 | |||||||||||||||
Installation Style | Wall-mounted | |||||||||||||||
Warranty | 5 Years (10 Years Optional) | |||||||||||||||
*Note: Five units in parallel has realized, ten units in parallel is under testing. Must use the inverters of the same model for parallel connecting. |