Model | SUN-29.9K-SG01HP3 SUN-30K-SG01HP3 -EU-BM3 -EU-BM3 | | SUN-35K-SG01HP3 -EU-BM3 | SUN-40K-SG01HP3 -EU-BM4 | SUN-50K-SG01HP3 -EU-BM4 |
Battery Input Data | |
Battery Type | Lithium-ion | |
Battery Voltage Range (V) | 160-800 |
Max. Charging Current (A) | 50+50 |
Max. Discharging Current (A) | 50+50 |
Number of Battery Input | 2 |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |
PV String Input Data | |
Max. DC Input Power (W) | 38870 | 39000 | 45500 | 52000 | 65000 |
Max. DC Input Voltage (V) | 1000 | |
Start-up Voltage (V) 180 |
MPPT Range (V) | 150-850 | |
Full Load DC Voltage Range (V) | 360-850 360-850 360-850 360-850 450-850 |
Rated DC Input Voltage (V) 600 |
PV Input Current (A) | 36+36+36+36 55+55+55+55 |
Max. PV ISC(A) |
No.of MPP Trackers | | 3 4 |
No.of Strings per MPP Tracker | 2+2+2 | | 2+2+2+2 |
AC Output Data | |
Rated AC Output Active Power (W) | 29900 | 30000 | 35000 | 40000 | 50000 |
Max AC Output Active Power (W) | 29900 | 30000 | 38500 | 44000 | 55000 |
AC Output Rated Current (A) | 45.4/43.4 | 45.5/43.5 | 53. 1/50.8 | 60.7/58 | 75.8/72.5 |
Max. AC Output Rated Current (A) | 45.4/43.4 | 50/47.8 | 58.4/55.8 | 66.7/63.8 | 83.4/79.7 |
Max. Three-phase Unbalanced Output Current (A) | 60 | 60 | 60 | 70 | 83.3 |
Max. Continuous AC Passthrough (A) 200 |
Peak Power (Off Grid) | 1.5 time of rated power, 10 S |
Generator Input/Smart Load /AC Couple Current (A) | 45.4 / 200 / 45.4 | 45.5 / 200 / 45.5 | 53.1 / 200 / 53.1 | | 75.8 / 200 / 75.8 |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac |
Grid Type | Three Phase |
Total Harmonic Distortion (THD) | <3% (of nominal power) |
DC Current Injection | <0.5% In | |
Efficiency | |
Max. Efficiency | 97.60% | |
Euro Efficiency | 97.00% |
MPPT Efficiency | 99.90% |
Protection | |
Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, |
| Output Shorted Protection, Surge Protection |
Over Voltage Category | DC Type II/AC Type III | |
Certifications and Standards | |
Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1, G98, G99, C10- 11, UNE217002, NBR16149/NBR16150 |
Safety EMC / Standard | IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2 |
General Data | |
Operating Temperature Range (C) | -40-60℃, >45℃ Derating |
Cooling | Smart Cooling |
Noise (dB) | ≤65 dB |
Communication with BMS | RS485; CAN |
Weight (kg) | 80 |
Cabinet Size (WxHxD mm) | 527×894×294 (Excluding Connectors and Brackets) |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
Warranty | 5 Years (10 Years Optional) |
*Note: Five units in parallel has realized, ten units in parallel is under testing. Must use the inverters of the same model for parallel connecting. |